loading

14 years optical transmitter,optical line terminal equipment,communication equipment experience

PRODUCT

Home  > PRODUCT  > Base Transceiver Station  > 

DBS3900 series Remote Radio Unit RRU3201 700MHz 260MHz

这里可以自定义设置
DBS3900 series Remote Radio Unit RRU3201 700MHz 260MHz
B站不支持收货地址
B站不支持库存规格
Model:
RRU3201
MOQ:
1piece
Payment:
T/T, Paypal, VISA, Western Union etc.
Delivery time:
7-15 working days up to quantities
Price term:
EXW, FOB, CIF, CFR, DDP etc.
Start Port:
Any port in China
Place of Origin:
China
Warranty:
90 days
参数暂无数据
多属性暂无数据
B站不支持优惠卷
暂无分享

Add success, do you want to check your shopping cart?

B站不支持产品保障


Product Introduction

An RRU3201, which is a remote radio unit for LTE FDD, supports two carriers.

Modes and frequency bands supported by an RRU3201:


Frequency Band(MHz)Receive Frequency Band (MHz)Transmit Frequency Band (MHz)ModeIBW (MHz)
RRU3201700 (band13)777 to 787746 to 756LTE FDD10
2600 (band7)2500 to 2570

Band C:2500 to 2520

Band D:2510 to 2560
Band E:2550 to 2570
2620 to 2690
Band C: 2620 to 2640
Band D:2630 to 2680
Band E:2670 to 2690
30

RF specifications of an RRU3201:


TX and RX Channel CapacityReceiver Sensitivity (dBm) Output Power
RRU32012T2R

700 MHz: One carrier with a bandwidth of 1.4, 3, 5 or 10 MHz

•2600 MHz: Two carriers. The bandwidth per carrier is 15 MHz or the continuous bandwidth of the two carriers is 10 MHz+10 MHz, or the bandwidth of one carrier is 20 MHz and the bandwidth of the other carrier is 10 MHz.

Receiver Sensitivi ty with One Antenna:-105.8

Receiver Sensitivi ty with Two Antennas:-108.6

The maximum power configurat ion is 2 x 40 W. For typical configurations.


Equipment specifications of an RRU3201:

Type Input Power Dimension (H x W x D) Weight (kg)
RRU3201-48 V DC; voltage range: -57 V DC to -36 V DC

480 mm x 270 mm x 140 mm (18 L, without the housing)

485 mm x 285 mm x 170 mm (23.5 L, with the housing)

≤ 17.5 (without the housing) 

≤ 19 (with the housing)


Environmental specifications of an RRU3201:


Operating Temperature Relative Humidity Absolute Humidity Atmospher ic Pressure Storage Time
RRU3201

• With solar radiatio n of 1120 W/m2: -40°C to +50°C

Without solar radiatio n: -40°C to +55°C

5% RH to 100% RH

1 g/m3 to 30 g/m3

70 kPa to 106 kPa It is recommende d that the device be installed and used within one year after its delivery because of the failure rate.


INQUIRY

Want more details please contact us

Chat Online 编辑模式下无法使用
Chat Online inputting...