loading

14 years optical transmitter,optical line terminal equipment,communication equipment experience

PRODUCT

Home  > PRODUCT  > Power Supply Equipment  > 

DC Power Supply Distribution Box DCPD6 for ZXSDR BBU

这里可以自定义设置
DC Power Supply Distribution Box DCPD6 for ZXSDR BBU
B站不支持收货地址
B站不支持库存规格
Model:
DCPD6
MOQ:
1set
Payment:
T/T, Paypal, VISA, Western Union etc
Delivery time:
15-30 working days up to quantities
Price term:
EXW, FOB, CIF, CFR, DDP etc
Start Port:
Any port in China
Place of Origin:
China
参数暂无数据
多属性暂无数据
B站不支持优惠卷
暂无分享

Add success, do you want to check your shopping cart?

B站不支持产品保障
该产品后台详情无内容

PRODUCT SPECIFICATIONS

Model

DCPD6

Dimensions (H*W*D)

482.6 mm x 228 mm x 43.6 mm

Weight

≤5KG

Input

-48V, 100A MAX

Output

-48V, 20A MAX.Per

Working temperature

-40℃ to 70℃

Relative humidity

10%-95%(25℃)

Atmosphere pressure

70kPa~106kPa

PRODUCT DETAILS

DC power supply distribution box DCPD6, installed in the cabinet and connected between - 48 V DC power supply and equipment, is a class C drawer type surge protective power supply cabinet. It is suitable to indoor low-voltage DC power distribution system for protection of equipment from surge and transient over-voltage caused by outside environment (such as lightning, EMI, switching effects of the system) or internal environment (power on and off, startup or shut off of inductance and capacitance loads, etc.)  with the following features.

• 19 inches 1U standard rack installation;

• 1 input and 9 outputs;

• Good insulation for output terminals

• Large discharge current and low residual voltage

• Remote signal alarm connectors (dry contacts of remote signal alarm is closed at normal operation while open at fault condition).

PRODUCT ADVANTAGES

• With 1 way input, 9 ways output lightning protection distribution function.
• Chase flow capacity, low residual pressure.

• The input can support A maximum current of 100 A, output 9 channels, and the maximum rated load current of each channel is 10 A / 20 A.
• Equipped with fault remote warning interface (dry contact signal).
• Adopt metal shell, protection grade IP2X, installed indoors, with good flame retardant.
• The front exit mode is adopted, which does not take up separate space

PRODUCT APPLICATION INTRODUCTION

DCPD6 series DC power distribution unit is used in low voltage dc power distribution system, connected in series in DC power supply between the line and the system equipment, as a result of external (lightning strikes, electromagnetic radiation interference, etc.) or system internal (the system closes effect、start and stop of inductive and capacitive loads,etc.) protective equipment for surge pulses and transient overvoltages caused by effects.

DCPD6 Power Distribution for BBU and RRU

PRODUCT DETAILS APPEARANCE

Chat Online 编辑模式下无法使用
Chat Online inputting...