Description | M6000-18S | M6000-8S | M6000-5S | M6000-3S | ||||
Height | AC/DC: 41U | AC: 18U DC: 14U | AC: 8U DC: 7U | AC: 5U DC: 4U | ||||
Weight | <250kg | <95kg | <55kg | <35kg | ||||
Service Slot | 18 | 8 | 5 | 3 | ||||
Main control redundancy | 1:1 | |||||||
Switch redundancy | 6+2 | 3+1 | 1+1 | Full-meshed | ||||
Interface type | POS | OC-768/STM-256, OC-192/STM-64, OC-48/STM-16, OC-12/STM-4, OC-3/STM-1 | ||||||
CPOS | OC-3c/ch.STM-1 | |||||||
Ethernet | 100GE, 40GE, 10GE, GE/FE | |||||||
TDM | E1/CE1 | |||||||
IPv4 | Unicast | Static routing and RIPv1/v2, OSPFv2, IS-ISv4, BGP-4 dynamic routing protocol. | ||||||
Policy routing, routing policy and routing load sharing. | ||||||||
Multicast | IGMPv1/v2/v3 | |||||||
Static multicast and PIM-DM/SM/SSM, PIM-SSM mapping, MSDP, MBGP dynamic multicast. | ||||||||
VPN multicast, multicast load sharing, controllable multicast | ||||||||
IPv6 | Unicast | Static routing and RIPng, OSPFv3, IS-ISv6, BGP4+ dynamic routing protocol. | ||||||
Policy routing, routing policy and routing load sharing. | ||||||||
Multicast | MLDv1/v2 | |||||||
Static multicast and PIM-DM/SM/SSM, MBGP dynamic multicast. | ||||||||
Interaction between v4/v6 | 4in6/ 6over4/ 6to4/ ISATAP tunnel, dual-stack + CGN, 6RD, DS-Lite, NAT444, IVI, NAT64+DNS64 | |||||||
MPLS | LDP, MPLS traffic load sharing, and MPLS label allocation policy. | |||||||
RSVP-TE and DS-TE | ||||||||
MPLS TE path end-to-end protection. | ||||||||
MPLS TE inter-domain. | ||||||||
MPLS TE bandwidth automatic adjustment. | ||||||||
Static TE tunnel | ||||||||
VPN | MPLS L2VPN (e.g., VPWS, VPLS/H-VPLS) and MPLS L3VPN, HoVPN. | |||||||
MPLS L2VPN (VPWS/VPLS) bridged into MPLS L3VPN | ||||||||
MPLS L2VPN/L3VPN FRR | ||||||||
6PE/6vPE, L2TP and GRE tunnel | ||||||||
IP RAN | PWE3 circuit simulation adapts to the all-IP development trend. | |||||||
1588v2 and Synchronous Ethernet services provide precise clock synchronization for IP RAN. | ||||||||
BRAS | Rich service access modes, e.g., IPoEv4/v6, PPPoEv4/v6, VPDN and IP leased line, etc. | |||||||
BRAS L3 access | ||||||||
Precise binding technologies, e.g., PPPoE+, DHCP option82, VBAS and QinQ, etc. | ||||||||
COA | ||||||||
ANCP (Access Node Control Protocol) | ||||||||
BRAS hot-backup technology. | ||||||||
NAT&CGN | IPv4 CGN | |||||||
IPv6 CGN, DS-Lite, 6RD, NAT64 and IVI, smoothly evolution to IPv6 | ||||||||
CGN hot-backup technology | ||||||||
QoS | H-QoS | |||||||
Flow classification/marking/priority mapping, flow policing and shaping | ||||||||
Perfect queuing, fair scheduling, bandwidth allocation, congestion management and resource reservation mechanism. | ||||||||
QoS based on the time period | ||||||||
OAM | SNMPv1/v2/v3 | |||||||
Alarm management, performance management, resource management, configuration management, SYSLOG, RMON. | ||||||||
Telnet, SSHv1/v2 | ||||||||
MPLS OAM, Ethernet OAM | ||||||||
SQA (Service Quality Analysis) | ||||||||
Security | port mirror and NetFlow v5/v9. | |||||||
Port protection, MAC filtering, TCP session control | ||||||||
Data plane security: ACL security filtering mechanism, uRPF, DHCP/IGMP/PIM Snooping | ||||||||
Control plane security: CPU protection, Anti-DDoS attack, MD5 authentication of routing protocol. | ||||||||
Management security: User authentication by local or RADIUS/TACACS+, Operation log while device access | ||||||||
CGN traceability | ||||||||
Reliability | Key components (e.g., MPU, SFU, Power supply and Fan modules) are redundancy design. | |||||||
Hot swapping is available for all cards. | ||||||||
Provide 99.999% carrier-grade system availability. | ||||||||
GR, NSF, NSR, IP/TE/LDP/VPN FRR, ISCU, VRRP and BFD, etc | ||||||||
Dimensions (H*W*D) mm | AC/DC: 1819.6*442*634 | AC: 797.3*442*749.4 DC: 619.5×442× 749.4 | AC: 352.8×442.0×740.0 DC: 308.3×442.0×740.0 | AC: 219.4×442.0× 738.0 DC: 175.0×442.0× 738.0 | ||||
Power supply | AC | AC: 90V~286V, 45~66Hz HVDC: 192V~380V Maximum outputs per module: < 2675W | 100V~127V/200V~240V, 43Hz~67Hz Maximum outputs per module: <2675W | |||||
8+8 | 3+3 | 2+2 | 1+1 | 1+1 | |||||
DC | -72V~-38V Maximum outputs per module: <2407.5W | -72V~-38V Maximum outputs per module: <2650W | ||||||
11+1 | 8+8 | 2+2 | 1+1 | 1+1 | |||||
Environment requirement | Operating temperature: -5°C~45°C. | |||||||
Working humidity: 5%~90% (Non-condensing). | ||||||||
Qualification certificate | CE, FCC, UL, CB, CC, RoHS, MEF CE2.0, MEF 9&14, EANTC |