W x D x H
Excluding mounting brackets:
442mmx268.7mmx88.1mm
Including IEc mounting brackets
4826mmx268.7mmx88.1mm
Including ETsI mounting brackets
535mmx268.7mmx88.1mm
Layer 2 features | |
VLAN+MAC forwarding | SVLAN+CVLAN forwarding |
PPPoE+ | DHCP option82 |
Layer 3 features | |
Static route | RIP/RIPng |
OSPF/OSPFv3 | IS-IS |
BGP/BGP4+ | ARP |
DHCP relay | VRF |
Multicast | |
IGMP v2/v3 | IGMP Proxy/Snooping |
MLD v1/v2 (V100R016C10 and later versions) | MLD Proxy/Snooping (V100R016C10 and later versions) |
VLAN-based IPTV multicast | IPv4 PIM and PIM-SSM (V100R017C00 and later versions) |
QoS | |
Traffic classification | Priority processing |
trTCM-based traffic policing | WRED |
Traffic shaping | HQoS |
PQ/WRR/PQ+WRR | ACL |
D-CCAP (V100R016C10 and later versions) | |
DOCSIS 3.1 | RF access and output |
CM management | Centralized management |
PacketCable | DOCSIS multicast |
EQAM | Admission control |
Built-in optical transceiver | SAV |
PNM | DSG (V100R018C10 and later versions) |
Digital IP Return and Forwarding (V100R019C12 and later versions) | |
MPLS&PWE3 | |
MPLS LDP | MPLS RSVP-TE |
MPLS OAM | MPLS BGP IP VPN |
PW protection switching | Tunnel protection switching |
TDM/ETH PWE3 | |
IPv6 | |
IPv4/IPv6 dual stack | IPv6 L2 and L3 forwarding |
DHCPv6 relay | |
System reliability | |
GPON type B/type C protection | ERPS (G.8032) |
BFD (V100R016C10 and later versions) | 10G GPON type B protection |
Monitor Link (V100R018C10 and later versions) | Intra-board and inter-board LAG |
Service overload control | MSTP |
2 control boards and 2 power boards for redundancy protection | In-service board fault detection and rectification |
In-service software upgrade (ISSU) of the control board | |
Eco-friendly and energy-saving | |
In compliance with the Code of Conduct v5 released by the European Commission | |
VXLAN (V100R018C00 and later versions) | |
Virtual eXtensible LAN | |
SRv6 (V100R019C10 and later versions) | |
Segment Routing IPv6 |
PRODUCT DETAILS
The MA5800 is the industry's first smart aggregation OLT with a distributed architecture. It is positioned as the next-generation OLT for NG-PON. The product is designed to help carriers build networks with larger bandwidths, higher speeds, and smarter connectivity to deliver better service experience.
•Providing GPON, 10G PON (including XG-PON and XGS-PON), P2P 10GE/GE access, the MA5800 supports deployment on FTTH, FTTD, FTTB, and FTTC networks. This makes it applicable to home access, enterprise access, mobile backhaul, and Wi-Fi hotspot backhaul scenarios to aggregate all services on one fiber network.
•The MA5800 functions as a large-capacity aggregation device on the network to aggregate the traffic from ONTs, MDUs, and campus switches, thereby simplifying the network architecture and reducing the OPEX.
SmartAX MA5800 series OLT products include the MA5800-X17, MA5800-X15, MA5800-X7, and MA5800-X2.
It supports GPON, XG-PON, XGS-PON, XG-PON&GPON combo, XGS-PON&GPON combo, Flex-PONGE, 10GE, and other interfaces.
The MA5800 supports four types of subracks. The only difference between these subracks relies on the service slot quantity (they have the same functions and network positions).
PRODUCT ADVANTAGES
Distributed architecture:
The MA5800 uses the distributed architecture (the same as the router). Under such an architecture, service processing on the control board is distributed to every service board, improving system switching capacity and performance, and reliability.
OPTIMUM VIDEO EXPERIENCE
The MA5800 supports distributed cache for fast 4K/8K video start or channel zapping
Supports VMOS video quality monitoring. Built-in probes on boards are used to collect video indicators and the NMS is used for remote monitoring and monitoring result query, improving video O&M experience.
Video service is not interrupted during an OLT upgrade, enhancing user experience.
PON COMBO
The MA5800 supports the PON combo technology, and can work with the built-in WDM1r optical module to support smooth evolution from GPON to XG(S)-PON.
FLEX-PON
A Flex-PON board supports GPON, XG-PON, XGS-PON, XG-PON&GPON combo, XGS-PON&GPON combo and TWDM PON with the corresponding optical module, and reduces OPEX by smooth evolution without board replacement.
W x D x H
Excluding mounting brackets:
442mmx268.7mmx88.1mm
Including IEc mounting brackets
4826mmx268.7mmx88.1mm
Including ETsI mounting brackets
535mmx268.7mmx88.1mm
W x D x H
Excluding mounting brackets
442 mm x 287 mm x 486mm
Including mounting brackets:
482.6 mm x 287 mm x 486 mm
W x D x H
Excluding mounting brackets:
442mmx268.7mmx263.9mm
Including lEc mounting brackets:
4826mmx268.7mmx263.9mm
Including ETsI mounting brackets:
535mmx268.7mmx263.9mm
W x D x H
Excluding mounting brackets
493 mm x 287 mm x 486 mm
Including mounting brackets:
535 mm x 287 mm x 486 mm
Item | MA5800-X17 | MA5800-X15 | MA5800-X7 | MA5800-X2 |
Supported cabinet | N63E-22 | N66E-22 | N63E-22, N66E-22 | N63E-22 |
Board configuration | Control board slot: 9,10 | Control board slot: 8,9 | Control board slot: 8,9 | Control board slot: 3,4 |
Service board or upstream interface board slot: 1-8,11-19 | Service board or upstream interface board slot: 1-7, 10–17 | Service board or upstream interface board slot: 1-7 | Service board or upstream interface board slot: 1-2 | |
Universal interface board slot: 0 | Universal interface board slot: 0 | Universal interface board slot: 0 | Do not support universal interface board | |
Power board slot: 20,21 | Power board slot: 18,19 | Power board slot: 10,11 | Power board slot: 0 | |
Dimensions (W x D x H) (mm) | Excluding mounting ears: 493x287x486 | Excluding mounting ears: 442x287x486 | Excluding mounting ears: 442x268.7x263.9 | Excluding mounting ears: 442x268.7x88.1 |
Including momounting ears: 535x287x486 | Including mounting ears: 482.6x287x486 | Including mounting ears of IEC standard: 482.6x268.7x263.9 | Including mounting ears of IEC standard: 482.6x268.7x88.1 | |
|
| Including mounting ears of ETSI standard:535x268.7x263.9 | Including mounting ears of ETSI standard:535x268.7x88.1 | |
Maximum weight (including mounting brackets) | 45 kg | 35 kg | 26 kg | 9.4 kg |
Maximum input current | 60 A | 60 A | 40 A | DC power supply: 20 A |
AC power supply: 8 A | ||||
Power supply mode | DC power support (dual for backup) | DC power support (dual for backup) | ||
AC power supply + battery for backup | ||||
Working voltage range | -38.4 V DC to -72 V DC | DC power supply: -38.4 V to -72 V | ||
AC power supply: 100 V to 240 V | ||||
Rated voltage | -48 V / -60 V | DC power supply: -48 V / -60 V | ||
AC power supply: 110 V / 220 V | ||||
Ambient temperature | -40°C to +65°C | |||
The MA5800 can start up at a lowest temperature of -25°C | ||||
NOTE: | ||||
The +65°C temperature refers to the highest temperature measured at the air intake vent of service subrack. | ||||
Ambient humidity | 5% RH to 95% RH | |||
Atmospheric pressure | 70 kPa to 106 kPa | |||
Altitude | < 4000 m, The air density varies with the altitude and will affect the heat dissipation of a device. Therefore, the working environment temperature of the MA5800 varies with the altitude | |||
Switching capacity of the control board (load sharing mode) | MPLA: 3.6 Tbit/s | MPSA: 248 Gbit/s | ||
MPLB: 7 Tbit/s | ||||
Maximum bandwidth per service slot (load sharing mode) | MPLA: 100 Gbit/s | MPSA: 40 Gbit/s | ||
MPLB: 200 Gbit/s | ||||
Maximum number of concurrent 4K video users | 16000 | 8000 | 2000 | |
Maximum number of MAC address | 262143 | |||
Maximum number of IPv4 routing tables | 65536 | |||
Maximum number of IPv6 routing tables | 16384 | |||
Maximum number of ARP tables | 131072 | 32768 | ||
Switching/Forwarding delay | Short forwarding delay: The 100 Mbit/s Ethernet port sends the 64-byte Ethernet packets at a delay shorter than 20 μs. | |||
Bit error rate (BER) in full load | A BER smaller than 10 e-7 for a port that transmits data in full load | |||
System reliability specifications | System availability for the typical configuration: > 99.999% | |||
Mean time between failures (MTBF): about 45 years. | ||||
NOTE: | ||||
Due to different network environments and different boards used by devices, the preceding MTBF (45 years) of the MA5800 is only for reference. The average repair time for field replaceable units (FRUs) is about 2 hours. The preceding values are only for reference. | ||||
GPON ports | 272 | 240 | 112 | 32 |
XG-PON ports | 272 | 240 | 112 | 32 |
XGS-PON ports | 272 | 240 | 112 | 32 |
10GE/GE ports | 136 | 120 | 56 | 16 |
PRODUCT APPLICATION INTRODUCTION
The MA5800 functions as a large-capacity aggregation device on the network to aggregate the traffic from ONTs, MDUs, and campus switches, thereby simplifying the network architecture and reducing the OPEX.
MA5800-X2
The MA5800-X2 service subrack has a fan tray on the right side. The subrack is installed in the cabinet through the mounting brackets
Copyright © 2019YANTAI YUNPAN INTERNATIONAL TRADE CO.,LTD. | All Rights Reserved
Hello, please leave your name and email here before chat online so that we won't miss your message and contact you smoothly.