OptiX OSN 580 Specification | Description |
Dimensions (H x W x D) | 221 mm x 442 mm x 224 mm |
Number of valid slots | DC power-supply chassis: 15 AC power-supply chassis: 12 |
Packet capacity | 560 Gbit/s |
TDM capacity | 280 Gbit/s higher order cross-connections and 20 Gbit/s lower order cross-connections |
Service type supported | SDH, PDH, Ethernet, PCM and others |
Network topology | Point-to-point, chain, star, ring, ring with chain, intersecting rings, tangent rings |
Network-level protection (packet) | MPLS-TP Tunnel 1:1 APS, MPLS-TP PW 1:1 APS/FPS, LPT, LAG, MC-LAG, MRPS, and ERPS |
Network-level protection (TDM) | SDH protection: linear MSP, ring MSP, SNCP, E1 SNCP, 64K SNCP, and hitless protection switching EoS protection: LCAS, LPT, STP/RSTP, LAG, and DLAG |
Device-level protection | 1+1 protection for the power supply board 1+1 protection for the system control, switching, and timing board Tributary protection switching (TPS) for E1/T1 services Fan protection (The failure in a single fan does not affect the operation of the other fans.) |
MPLS-TP OAM | Continuity check (CC), remote defect indication (RDI), alarm indication signal (AIS), loopback (LB), linktrace (LT), single-ended loss measurement (LM), two-way delay measurement (DM), LCK (only for bidirectional tunnels and PWs), TST, and CSF (only for E-Line services carried by PWs) |
ETH OAM (packet) | Packet: Ethernet service OAM: CC, LB, LT, AIS, LM (only single-ended LM), DM (only two-way DM), and RDI Ethernet port OAM: OAM auto-discovery, link performance monitoring, remote loopback, fault detection, and self-loop detection
TDM: Ethernet service OAM: CC, LB, LT, and OAM_Ping Ethernet port OAM: OAM auto-discovery, link performance monitoring, remote loopback, fault detection, and self-loop detection |
Packet Synchronization | Synchronous Ethernet Clock, IEEE 1588v2, and CES ACR |
TDM Synchronization | SDH Synchronization Clocks Synchronous Ethernet Clock |
Outband DCN | HWECC, IP over DCC |
Inband DCN | HWECC, IP |
Subrack temperature | Long-time operation: -5°C to +50°C Short-time operation: -10°C to +55°C |
Subrack humidity (relatively) | Long-time operation: 5%-85% Short-time operation: 5%-95% |