loading

14 years optical transmitter,optical line terminal equipment,communication equipment experience

PRODUCT

Home  > PRODUCT  > Base Transceiver Station  > 

RRU3240 2600MHz DBS3900 series Base station outdoor Remote radio unit RRU

这里可以自定义设置
RRU3240 2600MHz DBS3900 series Base station outdoor Remote radio unit RRU
B站不支持收货地址
B站不支持库存规格
Model:
RRU3240
MOQ:
1piece
Payment:
T/T, Paypal, VISA, Western Union etc.
Delivery time:
7-15 working days up to quantities
Price term:
EXW, FOB, CIF, CFR, DDP etc.
Start Port:
Any port in China
Place of Origin:
China
Warranty:
90 days
参数暂无数据
多属性暂无数据
B站不支持优惠卷
暂无分享

Add success, do you want to check your shopping cart?

B站不支持产品保障


Product Introduction

An RRU3240, which is a remote radio unit for LTE FDD, supports a maximum of two carriers.

Supported Modes and Frequency Bands




Frequency Band(MHz)

Receive Frequency Band (MHz)

Transmit Frequency Band (MHz)

Mode

IBW (MHz)

RRU3240

2600 (band 7)

2500 to 2570

2620 to 2690

LTE FDD

40



RF specifications of an RRU3240:


Type

Transmit And 

Receive

Channels

Capacity

Receiver Sensitivity(dBm)

Output Power

Receiver Sensitivity with One Antenna

Receiver Sensitivity with Two Antennas

RRU3240

2T4R

Two carriers. The bandwidth per carrier is 5, 10, 15, or 20 MHz.

-106.0

-108.8

The RRU3240 supports the maximum power configuration 2 x 40W. For typical configurations.


Equipment specifications of an RRU3240:


Type

Input Power

Dimension (H x W x D)

Weight (kg)

RRU3240

-48 V DC; voltage range: -57 V DC to-36 V DC

NOTE:

The RRU3240 supports AC power supply when connected to an external AC/DC power module or an OPM15M. For details, see AC/DC Power Module User Guide and OPM15M User Guide.

• 480 mm x 270 mm x 140mm (18 L, without the housing)

• 485 mm x 300 mm x 170mm (25 L, with the housing)

• ≤20 (without the housing)

•≤ 22 (with the housing)



Environmental specifications of an RRU3240:


Type

Operating Temperature

Relative Humidity

Absolute

Humidity

 

Atmosph

eric

Pressure

Storage Time

RRU3240

• With solar radiation of 1120W/m2: -40°C to +50°C

•Without solar radiation:-40°C to +55°C

5% RH to 100% RH

1 g/m3 to 30 g/m3

70 kPa to

106 kPa

It is recommended that the device be installed and used within one year after its delivery because of the failure rate.